Apex 2000 Series Delayed Egress

Apex 2000 Series Delayed Egress | PS160-6 Power Supply | Delayed Egress Application Charts | Delayed Egress Application Charts

 
 
 

DELAYED EGRESS

The Delayed Egress (DE) Exit Device provides a controlled egress for openings which require Panic or Fire Exit Hardware for safe egress. It is a self contained exit device, which when armed will deny exit to unauthorized personnel for 15 or 30 seconds, while simultaneously sounding a local or remote audible alarm. The Remote Monitoring feature will alert the security personnel that an attempt is being made to exit the opening. After the 15 (or 30) second delay of egress period the device will function as a standard exit device for safe egress.

 

OPERATION – The device secures the door in the locked mode with the Red LED indicating locked status. Depressing the Touchbar by accident or for less than the Nuisance Delay Time will sound the alarm without initiating the alarm sequence. Depressing the Touchbar with less than 15 pounds pressure, for longer than the Nuisance Delay Time will initiate an irreversible local audible beeping tone and a visual Red indicator until the device releases. After the delay egress time the lock releases and the alarm changes to a steady tone which continues to alarm until Reset. The remote monitoring contact output can be used to alert security personnel. The person depressing the Touchbar is denied egress (for 15 or 30 seconds) and security personnel are alerted for quick response.

 

TRIM – All standard device trims and functions are available, including “03” function, Trim Lock/Unlock will function normally even when the delayed egress feature is armed. The Device will only be affected when the Touchbar is depressed from the inside. All (DE) Rim and Mortise Devices are also available with Electric Lock/Unlock for the outside Trim. For details see page 28.

Available for all Apex Series Exit Devices.

The Delayed Egress Devices are manufactured and tested to exceed ANSI 156.3 and 156.24. Devices are UL Listed as a Controlled Exit Device (FULA) and Special Locking Arrangements (FWAX) category. Meets all requirements of NFPA 101.

 

FEATURES FIRE

ALARM CONTACTS – Fire Alarm input at any time will cut power to the delayed egress function and provide immediate egress.

 

ARMED-MOMENTARY EGRESS – Turning the key clockwise allowsauthorized personnel to exit without alarming. At the end of the field selectable time period (10, 20 or 30 seconds), the device will relock and rearm.

 

DE-DEVICE NETWORKING FEATURE – This feature allows a Delayed Egress device to arm, alarm, reset and disarm all devices on the same circuit. Each device will continue to operate independently for Momentary Egress.

 

30 SECOND DELAY – A 30 second delay option is available. A written approval from the authority having jurisdiction is required. Note: A “30 Second” decal is provided when the 30 Second Delay option is specified.

 

NUISANCE DELAY TIME – A Nuisance Delay Time helps avoid inadvertent activation. The alarm will sound when the touchbar is pressed, but the alarm sequence will not start unless the touch bar is held in for more than the Nuisance Delay Time. Delay Time is field selectable for 0, 1, 2 or 3 seconds.

 

INTEGRAL KEY SWITCH

Arm – The Key switch provides the means to locally arm the (DE) device.

Momentary Egress – The Key switch will provide temporary disarming to allow for momentary egress (10, 20 or 30 seconds) when the device is in the armed state. The Key switch will Disarm the device and it will function as a standard exit device.

Reset – During alarm sequence the device can be rearmed by the Key Switch.

Requires the use of a 1-1/4 mortise cylinder, not furnished standard. Specify when required.

 

LED STATUS INDICATOR (in the device) - A color coded LED indicates Arm, Disarm and Alarm status.

Flashing Green – Arming

Flashing Red – Armed

Green – Unarmed

Red – Alarmed

Off – No Power to Device (Normal Exit)

 

INTERNAL ALARM – The device has a 85 db horn which will sound until the device is reset.

 

EXTERNAL ALARM – A set of relay contacts rated at (1 amp, 24VDC) are provided for activating external local or remote audible/visual signaling devices.

 

EXTERNAL INHIBIT

Arm/Rearm – Accepts a contact to Arm/Rearm the device.

Momentary Egress – Accepts a contact to provide temporary disarming to allow for momentary egress when the device is in the armed state. The Momentary Egress will be engaged as long as the switch closure is maintained.

Reset – Accepts a contact to reset the device during alarm.

 

DOOR POSITION SWITCH – used in conjunction with the Delayed Egress Exit Device, the following security features are added: The Exit Device Alarm will sound if the door is not closed when the device is armed. The Alarm will sound if the door is forced open when the device is armed. While the device is in the arming stage you may exit the opening. When the door closes the arm/rearm time is cut short and the device is armed preventing unauthorized tailgating through the opening.

Top of Page

 

 

 

PS160-6 Power Supply

Required for Delayed Egress Devices

The PS160-6 Power Supply is designed as a power source for a variety of applications including Electric Locking, Exit Alarm and Delayed Egress Exit Devices.

The Power Supply uses a standard 115 VAC at 2.5 ampere input fuse rated@3.5 ampere, 250 volts. The power supply can control up to (3) Delayed Egress Exit Devices. Note: Adding additional loads to the PS160-6 Power Supply i.e., Card readers, Horns, etc...will reduce the quantity of Delay Egress Exit Devices that may be energized by the powersource. The filtered and regulated out put power is field selectable for 12 or 24 VDC at 6 amp.

 

SPECIFICATIONS

• Fire alarm release that accepts normally closed contact

• Battery Backup with charger (27 VDC, 150mA)

• AC input is protected via a manually reset circuit breaker

• DC output is protected via an auto-reset fuse (PTC)

• LED indicators for AC input, DC output and Battery Backup status

• Includes lockable box with key lock

• Dimensions: 13 W x 13.5 H x 3.25 D (18 gage steel)

• Weight: 11 lbs.

 

To Order: specify PS160-6 power supply

Top of Page

 

 

 

DELAYED EGRESS APPLICATION CHARTS

ACCESS COVER FEATURE - The Mode Select Switch panel can be accessed through a hinge stile cover for ease of installation and maintenance without removing the device or Endcap Mounting Bracket. The access cover is secured in place by the device Endcap, which is attached with Security Screws.

 

MODE SELECT SWITCHES - The following Mode Select Switch panel (see left) provides field selectable settings to suit the various Delayed Egress applications.

Top of Page

 

 

 

DELAYED EGRESS APPLICATION CHARTS

SINGLE DOOR - This application allows for remote Arm/Disarm and remote monitoring of the Delayed Egress. The Exit device will delay egress when armed and will be a normal exit device when disarmed. The DS880 (DS) Door Position Switch (page 29) prohibits the door from being held or forced open while the device is armed. The 24 VDC, remote switch, remote horn and the DS are routed through the power transfer and the fire alarm is wired to the power supply.

 

DOUBLE DOOR - This application allows for remote Arm/Disarm and remote monitoring of the Delayed Egress. The Exit device will delay egress when armed and will be a normal exit device when disarmed. The DS880 (DS) Door Position Switch (page 29) prohibits the door from being held or forced open while the device is armed. When one device is alarmed the other device will also go into alarm. The 24 VDC, remote switch, remote horn and the DS are routed through the power transfer and the fire alarm is wired to the power supply.

Top of Page

 
 

 

Apex 2000 Delayed Egress

Download the Brochure here
 

 

Corporate Brochure

Download the Corporate Brochure here
 

 

Mechanical Access

Download this Brochure here
 
   
  © 2006 Stanley Security Solutions, Inc.
6161 East 75th Street | Indianapolis, IN | 46250
Tel 317 849 2250
Terms of Use